Maintain PD Fail History 的技巧與實例

    內容表格
    沒有標頭

    版本為 03:54, 24 Nov 2024

    到這個版本。

    返回到 版本存檔.

    查閱目前版本

    本篇擷取自於LSI KB16570知識庫. 用來說明Maintain PD Fail History使用技巧以及實例說明.
    http://kb.lsi.com/KnowledgebaseArticle16570.aspx
    MegaRAID Feature: Maintain PD Fail History
    This KB article explains the 'Maintain PD (Physical Disk) Failed History feature that is in the LSI MegaRAID LSISAS2108 and LSISAS2208 based products.
    Overview:
    If enabled (the default), if a disk drive drops from a volume, it can not be used again in the volume with manual intervention in the event the drive comes back. Warning: See KB16511 regarding having this feature enabled with single drive RAID 0 volumes.

    If disabled, if a disk drive drops from a volume (e.g. the cable gets disconnected) if the drive is redetected by the controller (e.g. the cable is reconnected), then the volume will automatically rebuild with the drive without any manual intervention required.
    Enabling/Disabling/Checking Current Value of "Maintain PD Fail History "
    Using WebBIOS
    1. Boot the system into the MegaRAID WebBIOS. Click on 'Controller Properties':

    Powered by MindTouch Core