    Notes:

    • If controller setting MaintainPdFailHistory is turned on, the controller will keep track of the drive history, so if a drive is removed and re-inserted the drive will be marked as unconfigured bad, then the user can change the state to unconfigured good.
    • If controller setting MaintainPdFailHistory is turned off, when a drive is removed and re-inserted the drive will be marked as un configured good.


    本篇擷取自於LSI KB16570知識庫. 用來說明Maintain PD Fail History使用技巧以及實例說明.
    http://kb.lsi.com/KnowledgebaseArticle16570.aspx
    MegaRAID Feature: Maintain PD Fail History
    This KB article explains the 'Maintain PD (Physical Disk) Failed History feature that is in the LSI MegaRAID LSISAS2108 and LSISAS2208 based products.
    Overview:
    If enabled (the default), if a disk drive drops from a volume, it can not be used again in the volume with manual intervention in the event the drive comes back. Warning: See KB16511 regarding having this feature enabled with single drive RAID 0 volumes.

    If disabled, if a disk drive drops from a volume (e.g. the cable gets disconnected) if the drive is redetected by the controller (e.g. the cable is reconnected), then the volume will automatically rebuild with the drive without any manual intervention required.
    Enabling/Disabling/Checking Current Value of "Maintain PD Fail History "
    Using WebBIOS
    1. Boot the system into the MegaRAID WebBIOS. Click on 'Controller Properties':
    step1.png
    2. The first screen shows version information for the controller. The screen shots are for firmware version 2.130.03-1332 (the latest available when this KB article was authored). Older/newer WebBIOS screen may vary slightly.
    step2.png
    Click Next to see options that can be configured:
    step3.png
    Click Next to see the screen that shows 'Maintain PD Fail History'. The drop down box will show the currently set value (Enabled by default).
    step4.png
    Select Enabled or Disabled from the drop down box, then Submit to save the change.
    step5.png
    Using MegaRAID Storage Manager (MSM)
    It is not possible to use MSM to enable, disable, or check the current value of the "Maintain PD Fail History" setting.

    Using MegaCLI
    (use MegaCLI.exe for 32-bit OS and MegaCLI64.exe for 64-bit OS)

    To check the current setting:
    MegaCLI -AdpGetProp MaintainPDFailHistoryEnbl -a<adapter number>
    e.g. MegaCLI -AdpGetProp MaintainPDFailHistoryEnbl -a0
    step6.png
    To enable "Maintain PD Fail History"
    MegaCLI -AdpSetProp MaintainPDFailHistoryEnbl -<0 to disable or 1 to enable >-a<adapter number>
    e.g. MegaCLI -AdpGetProp MaintainPDFailHistoryEnbl -1 -a0
    step7.png
    To disable "Maintain PD Fail History"
    MegaCLI -AdpSetProp MaintainPDFailHistoryEnbl -<0 to disable or 1 to enable >-a<adapter number>
    e.g. MegaCLI -AdpGetProp MaintainPDFailHistoryEnbl -0 -a0
    step8.png

    Examples:
    1. If "Maintain PD Fail History" is enabled (the default):
    Volume starts out as optimal:
    ex1.png
    Drive drops from the volume (e.g. cable becomes unplugged). Volume degrades:
    ex2.png
    Drive is again available (e.g. cable is reconnected). The drive shows up under 'Unconfigured Drives', as (Foreign) Unconfigured Bad under the Logical tab:
    ex3.png
    Under the Physical tab, the drive shows up as (Foreign) Unconfigured Bad:
    ex4.png
    From the Logical tab, right mouse click on the (Foreign) Unconfigured Bad drive:
    ex5.png
    Click on 'Change to Unconfigured Good'. The drive will now be listed as 'Unconfigured Good':
    ex6.png
    Right mouse click on the controller and select 'Scan Foreign Configuration':
    ex7.png
    Select 'Clear: Remove logical configuration from all foreign drives.':
    ex8.png

    ex9.png
    You will see this message, and the drive will again be available for use:
    ex10.png
    The drive now shows up as 'Unconfigured Good' under the Physical tab:
    ex11.png
    At this point the volume is still degraded. To rebuild the volume, the 'Unconfigured Good' drive will need to be configured to a Hot Spare.
    Right mouse click on the 'Unconfigured Good' drive, and click on 'Assign Global Hot Spare':
    ex12.png
    Once this is done, the rebuild will begin immediately:
    ex13.png ex14.png ex15.png

    2. If "Maintain PD Fail History" is disabled:
    Volume starts out as optimal:
    ex16.png
    Drive drops from the volume (e.g. cable becomes unplugged). Volume degrades:
    ex17.png
    Drive is again available (e.g. cable is reconnected). The rebuild of the volume automatically starts, without any user intervention:
    ex18.png ex19.png
     